standard by ASTM International, 05/01/2014
Warning: Last items in stock!
Availability date:
1.1This practice covers guidelines for evaluating precision and serves as the governing practice for interlaboratory test programs (ITP) used to evaluate precision for test methods as used in the rubber manufacturing and the carbon black industries. This practice uses the basic one way analysis of variance calculation algorithms of Practice E691. Although bias is not evaluated in this practice, it is an essential concept in understanding precision evaluation.
1.2This practice applies to test methods that have test results expressed in terms of a quantitative continuous variable. Although exceptions may occur, it is in general limited to test methods that are fully developed and in routine use in a number of laboratories.
1.3Two precision evaluation methods are given that are described as robust statistical procedures that attempt to eliminate or substantially decrease the influence of outliers. The first is a General Precision procedure intended for all test methods in the rubber manufacturing industry, and the second is a specific variation of the general precision procedure designated as Special Precision, that applies to carbon black testing. Both of these procedures use the same uniform level experimental design and the Mandel h and k statistics to review the precision database for potential outliers. However, they use slight modifications in the procedure for rejecting incompatible data values as outliers. The Special Precision procedure is specific as to the number of replicates per database cell or material-laboratory combination.
1.4This practice is divided into the following sections:
Section | |
Scope | 1 |
Referenced Documents | 2 |
Terminology | 3 |
Significance and Use | 4 |
Precision Evaluation-General Precision and Special Precision | 5 |
Steps in Organizing an Interlaboratory Test Program (ITP) | 6 |
Overview of the General Precision Analysis Procedure | 7 |
General Precision: Analysis Step 1 | 8 |
Preliminary Graphical Data Review | 8.1 |
Calculation of Precision for Original Database | 8.2 |
Detection of Outliers at 5% Significance Level Using h and k Statistics | 8.3 |
Generation of Revision 1 Database Using Outlier Treatment Option 1 or 2 | 8.4 |
General Precision: Analysis Step 2 | 9 |
Calculation of Precision for Revision 1 Database | 9.1 |
Detection of Outliers at 2% Significance Level Using h and k Statistics | 9.1 |
Generation of Revision 2 Database Using Outlier Treatment Option 1 or 2 | 9.1.2 |
General Precision: Analysis Step 3 | 10 |
Calculation of Precision Using Revision 2 Database | 10.1 |
Special Precision Analysis-Carbon Black Testing | 11 |
Format for Precision Table and Clause in Test Method Standards | 12 |
Preparation of Report for Precision Analysis | 13 |
Definitions for Selected Terms Concerned with Precision and Testing | Annex A1 |
Statistical Model for Interlaboratory Testing Programs | Annex A2 |
Calculating the h and k Consistency Statistics for Outliers | Annex A3 |
Spreadsheet Calculation Formulas, Table Layout, and Calculation Sequence | Annex A4 |
Procedure for Calculating Replacement Values of Deleted Outliers | Annex A5 |
Example of General Precision Evaluation-Mooney Viscosity Testing | Annex A6 |
1.5Six annexes are presented; these serve as supplements to the main body of this practice. Annex A1 and Annex A2 are given mainly as background information that is important for a full understanding of precision evaluation. Annex A3 - Annex A5 contain detailed instructions and procedures needed to perform the operations as called for in various parts of the practice. The use of these annexes in this capacity avoids long sections of involved instruction in the main body of this practice. This allows for a better presentation and understanding of the central concepts involved in the evaluation of precision. Annex A6 is also important; it gives a complete example of precision evaluation that illustrates all of the procedures and options likely to be encountered in any precision evaluation, from the simple to the most complex.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.