Sale! View larger

ASTM F519-13

New product

ASTM F519-13 Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments

standard by ASTM International, 12/01/2013

More details

$26.83

-57%

$62.40

More info

Full Description

1.1This test method describes mechanical test methods and defines acceptance criteria for coating and plating processes that can cause hydrogen embrittlement in steels. Subsequent exposure to chemicals encountered in service environments, such as fluids, cleaning treatments or maintenance chemicals that come in contact with the plated/coated or bare surface of the steel, can also be evaluated.

1.2This test method is not intended to measure the relative susceptibility of different steels. The relative susceptibility of different materials to hydrogen embrittlement may be determined in accordance with Test Method F1459 and Test Method F1624.

1.3This test method specifies the use of air melted AISI E4340 steel per SAE AMS-S-5000 (formerly MIL-S-5000) heat treated to 260 to 280 ksi (pounds per square inch 1000) as the baseline. This combination of alloy and heat treat level has been used for many years and a large database has been accumulated in the aerospace industry on its specific response to exposure to a wide variety of maintenance chemicals, or electroplated coatings, or both. Components with ultimate strengths higher than 260 to 280 ksi may not be represented by the baseline. In such cases, the cognizant engineering authority shall determine the need for manufacturing specimens from the specific material and heat treat condition of the component. Deviations from the baseline shall be reported as required by 12.1.2. The sensitivity to hydrogen embrittlement shall be demonstrated for each lot of specimens as specified in 9.5.

1.4Test procedures and acceptance requirements are specified for seven specimens of different sizes, geometries, and loading configurations.

1.5Pass/Fail Requirements-For plating/coating processes, specimens must meet or exceed 200 h using a sustained load test (SLT) at the levels shown in Table 3.

TABLE 1 Lot Acceptance Criteria for Notched Specimens

Type

Item

Sampling of
Each Lot

Requirement/Method

1

Tensile Strength

4 each

Test Method E8. Tensile strength of each specimen must be within 10 ksi of the average.

1

HardnessA

5%

51 to 53 HRC per Test Methods E18.
Round the average of
three readings per
specimen per Practice
E29.

1

Dimensions

100%

Meet tolerances of
corresponding
drawings. Notch
dimension verified with
shadow graphic
projection at 50 to
100 or equivalent.

1

Notched Fracture Strength (NFS)

10 ea

Test Methods E8/E8M. NFS of each specimen
must be within 10 ksi
of the average.

1c

Self-loading
notched round
specimen bend
fixture, Fig. A2.7

10 ea

Alternate: The number of
turns of the loading
bolt, which is required
to produce fracture in
each specimen, must be
within 5% of the
average.

1d

Self-loading
notched C-Ring
bend fixture,
Fig. A2.8

10 ea

Alternate: The change in
diameter at fracture
load for each specimen
must be within 0.008
inches of the average.

AIf the hardness requirements of any of the sampled specimens are not satisfied, only those specimens of the lot that are individually inspected for conformance to these requirements shall be used for testing.TABLE 2 Electroplating Bath Compositions and Operating Conditions for Sensitivity Test

Item

Treatment A

Treatment B

Bath composition:

Range

Optimum

Cadmium (as CdO)

2.9 to 5.5 oz/gal (22 to 41 g/L)

4.5 oz/gal (33.7 g/L)

same as Treatment A

Total Sodium cyanide
(NaCN)

12.0 to 16.0 oz/gal (89.9 to 120 g/L)

14 oz/gal (104 g/L)

same as Treatment A

Ratio NaCN to CdO

2.8/1 to 6.0/1

3.0/1

same as Treatment A

pH

12.0 or greater

12.0

same as Treatment A

Temperature

70-90F (21-32C)

75F (24C)

same as Treatment A

Sodium hydroxide
(NaOH)A

1.0 to 3.2 oz/gal (7.5 to 24.0 g/L)

2.5 oz/gal (18.7 g/L)

same as Treatment A

Brightener such as
Colcad 100B or
equivalent

Manufacturers suggested range

None

Electroplating current

10 A/ft2 (108 A/m)

60 A/ft2 (645 A/m 2)

Electroplating time

30 minutes

6 minutes

Baking

Baking temperature

375 25F (190 14C)

same as Treatment A

Baking time: Type 1
Specimen

Do Not Bake

23 h

Baking time: Type 2a
Specimen

8 h

23 h

Chromate TreatmentC

Yes

same as Treatment A

A Addition of sodium hydroxide may not be required on solution makeup, since the addition of 1 oz/gal of cadmium oxide is equivalent to 0.6 oz/gal of free hydroxide.BThe sole source of manufacture of Colcad 100 known to the committee at this time is Columbia Chemical in Brunswick, Ohio, www.columbiachemical.com. If you are aware of alternative manufacturers, please provide this information to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.C After baking, the specimens shall be dipped into any appropriate chromate conversion coating solution for minimum time that will produce an adherent and continuous coating as described in AMS-QQ-P-416 Type II.TABLE 3 Pass/Fail Loading Requirements of Test Specimens

Type 1a, 1b, 1c, 1d, 1e

75% of the tensile or bend NFS (Table 1).

Type 2a

92% of the Test Methods E8/E8M, E4 ultimate strength, obtained bydeflecting a 2.300-inch diameter O-Ring specimenwith a 2.525-inch stressing bar.


1.5.1The loading conditions and pass/fail requirements for service environments are specified in Annex A5.

1.5.2If approved by the cognizant engineering authority, a quantitative, accelerated ( 24 h) incremental step-load (ISL) test as defined in Annex A3 may be used as an alternative to SLT.

1.6This test method is divided into two parts. The first part gives general information concerning requirements for hydrogen embrittlement testing. The second is composed of annexes that give specific requirements for the various loading and specimen configurations covered by this test method (see section 9.1 for a list of types) and the details for testing service environments.

1.7The values stated in the foot-pound-second (fps) system in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published: 12/01/2013 Number of Pages: 18File Size: 1 file , 240 KBRedline File Size:2files, 500 KB