Sale! View larger

ASTM C1126-12a

New product

ASTM C1126-12a Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

standard by ASTM International, 11/01/2012

More details

$23.74

-57%

$55.20

More info

Full Description

1.1This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced. Tubular forms covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials.

Note 1-If a facer or vapor retarder is to be used for the tubular form, then refer to Practice C921.

1.2Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe insulation for use between40 and 257F (40 and 125C). Type II and Type III materials with an appropriate vapor retarder covering on the warm surface are used to a lower temperature limit of 290F (180C). (See 7.2.)

1.3The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4This specification covers closed cell rigid cellular phenolic thermal insulation manufactured using blowing agents with an ozone depletion of 0 (ODP=0).

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

For specific precautionary statements, see Section 16.

Product Details

Published: 11/01/2012 Number of Pages: 5File Size: 1 file , 95 KBRedline File Size:2files, 170 KB