Sale! View larger

AC-2755 -- The Performance of a Natural-Circulation Solar Air Heater

New product

AC-2755 -- The Performance of a Natural-Circulation Solar Air Heater

Conference Proceeding by ASHRAE, 1983

R. Mastrullo; P. Mazzei; P. Vigo

More details

$6.60

-56%

$15.00

More info

Full Description

This paper presents a methodology to predict the performance of a natural-circulation solar air heater. The forcing functions are monthly mean hourly values, and both the diurnal and seasonal cycles are considered. Results are for Naples, Italy, 40.85N latitude, for a single south-oriented vertical glass and for a winter period of October to March. The seasonal useful collected energy corresponds to an average value of 2.77 MJ/m per day. The following heat-removal factor and overall heat-loss coefficient are suggested:

FR = 0.56 +/- 5%, UL = 4.6 +/- 5% W/m x K

Citation: ASHRAE Transactions, 1983, vol. 89, pt. 1A, Atlantic City, NJ

Product Details

Published: 1983 Number of Pages: 11File Size: 1 file , 790 KB Product Code(s): D-AC-2755