New product
standard by ASTM International, 07/01/2013
Warning: Last items in stock!
Availability date:
1.1These test methods cover the determination of wet film thickness of organic coatings such as paint, varnish, and lacquer. Two methods are described as follows:
1.1.1In Test Method A, the Wet Film Thickness Gage (English or Metric graduation (see 5.1)) is used to measure wet film thicknesses up to 60 mils on the English scale series, and up to 700 m on the metric scale series (Sections 5-8).
1.1.2In Test Method B, the Pfund Gage is used to measure wet film thicknesses up to 14.2 mils (360 m) (Sections 9-13).
1.2The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.